ESXI5-VMNET-000005 - All vSwitch and VLAN IDs must be fully documented - 'vSwitch labels'

Details

VLAN tagging used on a vSwitch must correspond to the IDs on external VLAN-aware upstream switches, if any. If VLAN IDs are not tracked completely, mistaken re-use of IDs could allow for traffic to be allowed between inappropriate physical and virtual machines. Similarly, wrong or missing VLAN IDs may lead to traffic not passing between appropriate physical and virtual machines.


Solution

From the vSphere Client/vCenter: Go to 'Home>> Inventory>> Hosts and Clusters'. Select each ESXi host with virtual switches connected to active VMs. Go to 'Configuration>> Network>> vSwitch(?)>> Properties>> Ports>> [Portgroup Name]>> VLAN ID'. Record all VLAN IDs in a (site-specific) tracking system.


Supportive Information

The following resource is also helpful.

This security hardening control applies to the following category of controls within NIST 800-53: Configuration Management.This control applies to the following type of system VMware.


References


Source